CT
Both industrial non-destructive testing and radiological (CB)CT require large 3D volumes with high resolution and fine texture fidelity to detect defects, perform diagnoses, or plan radiotherapy. Accelerated scanning, limited-angle, robotic-controlled or time-resolved imaging introduce streaking, reduced contrast, hazing and loss of fine structural detail with classical reconstruction algorithms such as FDK. Reconstruct Anything Model 3D reconstructs clean and physically accurate CT volumes from any geometry of incomplete or noisy radiographs, even in the presence of geometry miscalibration or motion corruption, enabling faster inspection of critical details in images.

Benchmark performance
See Gallery below for sample images
| PSNR (dB) (higher is better) | ||||
|---|---|---|---|---|
| Family | Task | RAM 2 | RAM 1(ICLR'26) | Task-specific model |
| CT | Sparse-view CT reconstruction2DeteCT benchmark test (10×) | 34.1 | 32.6 | 33.4LPD |
| Limited-angle CT reconstruction2DeteCT benchmark test (3×) | 31.2 | 27.0 | 31.1LPD | |
For blind problems where the physics is not fully known (e.g. noise level, blur PSF, coil maps), we report results with physics estimators trained in-house. Either use open-source estimators in DeepInverse ↗ or use them via Labs ↗.
Industrial miscalibrated micro-CBCT
Source: Zeiss Xradia Context micro-CT of a rock core at 19 µm voxels. Imperfect geometry calibrated, detector blur and beam-hardening modelled.
Data from Shi et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Industrial micro-CT with beam hardening
Source: TESCAN UniTOM XL micro-CT of a metal gear at 0.16 mm voxels. 100 projections at 75 kV.
Data from Collins et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Industrial computed laminography
Source: Nikon XTH 225 laminography of plastic at 0.165 mm voxels. 628 projections at 80 kV.
Data from Fisher et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
4D free-breathing time-resolved CBCT
Source: Varian TrueBeam kV CBCT. Free-breathing 1 min rotation of 600 views.
Not for clinical use. Data from Hering et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
3D free-breathing motion-compensated CBCT
Source: Varian TrueBeam kV CBCT. Free-breathing 1 min rotation of 600 views.
Not for clinical use. Data from Hering et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
3D isotropic parallel-beam CT
Source: Siemens SOMATOM go.Fit abdominal CT, 6 mm slices.
Not for clinical use. Data from Wu et al., CC BY-NC 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Limited-angle thin-slice tomosynthesis
Source: GE VolumeRad digital tomosynthesis. 2x accelerated acquisition.
Not for clinical use. Data from Wu et al., CC BY-NC 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Sparse-view accelerated CT

Limited-angle CT