Nuclear medicine
In nuclear medicine, expensive hardware, long acquisition times or high dose are traditionally needed to collect enough photons to reconstruct volumes for diagnosis and dosimetry, yet the image quality hides critical information in the extreme blur and noise. Lesion detectability and quantification still suffer due to weak reconstruction algorithms, poor physics modelling or challenging detector geometries. For example, clinical SPECT is characterised by challenging noise statistics, PVEs, collimator blur, and few sampling angles, whereas next-generation PET moves towards shorter time windows, novel limited-angle geometries, and huge ToF information. In all cases, classical iterative algorithms end up reconstructing high noise/blur images or discarding precious ToF information. Reconstruct Anything Model 3D reconstructs images of unprecedented quality while preserving quantitative consistency, enabling next-order throughput cancer imaging and theranostics.


Benchmark performance
See Gallery below for sample images
| PSNR (dB) (higher is better) | ||||
|---|---|---|---|---|
| Family | Task | RAM 2 | RAM 1(ICLR'26) | Task-specific model |
| PET | PET reconstructionNEMA phantom simulation | 37.4 | 21.3 | 30.5OSEM |
For blind problems where the physics is not fully known (e.g. noise level, blur PSF, coil maps), we report results with physics estimators trained in-house. Either use open-source estimators in DeepInverse ↗ or use them via Labs ↗.
Clinical low-dose PET
Source: GE Discovery MI PET/CT. 25 MBq F-18 FDG NEMA phantom at half dose (3 min).
Not for clinical use. Data from Schramm et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Dual-panel limited-angle PET
Source: Simulated proprietary system. 2.6 MBq phantom over 10 min scan.
Not for clinical use. Images shown are of measurements reconstructed with baseline and RAM 3D.
Time-of-flight brain PET
Source: Siemens Biograph Vision 600 PET/CT of Hoffman 3D brain phantom.
Not for clinical use. Data from Li et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Accelerated clinical SPECT
Source: GE Discovery 670 Pro. Lu-177 PSMA multi-bed scan (25 min).
Not for clinical use. Data from Polson et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
12-detector CZT SPECT
Source: GE StarGuide 12-detector CZT SPECT/CT. Tc-99m sphere phantom, 64 min acquisition.
Not for clinical use. Data from Polson et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.