As MRI accelerates and develops, clinical acquisitions face myriad artifacts: aliasing caused by undersampling spokes or lines, B0 inhomogeneity sensitivity and off-resonance due to long readouts, low SNR or resolution at ultra low-field, or motion artifacts in free-breathing, even despite advances in motion-robust sampling patterns. Deep learning reconstruction for MRI has resulted in a promise of accelerated acquisition and cleaner images, but real acquisition often results in data falling outside the training dataset, leading to hallucinations. Reconstruct Anything Model 3D reconstructs clean and quantitative volumes from any acquisition sequence (including non-Cartesian), degradation or anatomy, even in the presence of motion corruption or coil map misestimation, without needing to retrain every time.

Benchmark performance
See Gallery below for sample images
| PSNR (dB) (higher is better) | ||||
|---|---|---|---|---|
| Family | Task | RAM 2 | RAM 1(ICLR'26) | Task-specific model |
| MRI | Accelerated MRI reconstructionCMRxRecon 2025 test (cardiac black-blood, 8×) | 44.5* | 41.6 | 44.4NVIDIA Raw2Insights |
| Accelerated MRI reconstructionCalgary-Campinas 2.0 test (brain T1w, 10×) | 32.5* | 28.3 | 33.0CC-PromptMR+ | |
| Non-Cartesian accelerated MRIfastMRI breast (DCE, 4×) | 31.3* | 29.8 | 21.2CG | |
For blind problems where the physics is not fully known (e.g. noise level, blur PSF, coil maps), we report results with physics estimators trained in-house. Either use open-source estimators in DeepInverse ↗ or use them via Labs ↗.
4D isotropic cardiac MRI
Source: Siemens MAGNETOM Avanto 1.5T. Ungated real-time 2D bSSFP during breath-hold at 4x prospective undersampling, 6 mm slices.
Not for clinical use. Data from AMRG Cardiac Atlas, Auckland MRI Research Group. Images shown are of measurements reconstructed with baseline and RAM 3D.
3D motion-compensated brain MRI
Source: Philips Achieva 7T. 3D MP2RAGE at 4x variable-density acceleration.
Not for clinical use. Data from Caan et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
Ultra-low-field portable MRI
Source: 64 mT portable scanner simulation, 3D T1w at 1.5 x 1.5 x 5 mm.
Not for clinical use. Data from van den Broek et al., MIT. Images shown are of measurements reconstructed with baseline and RAM 3D.
4D free-breathing time-resolved MRI
Source: Siemens MAGNETOM Skyra 3T. 1 min free-breathing 3D GRE, variable-density Cartesian.
Not for clinical use. Data from Wasserthal et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
3D free-breathing motion-compensated MRI
Source: Siemens MAGNETOM Skyra 3T. 1 min free-breathing 3D GRE, variable-density Cartesian.
Not for clinical use. Data from Wasserthal et al., CC BY 4.0. Images shown are of measurements reconstructed with baseline and RAM 3D.
3D accelerated non-Cartesian breast MRI
Source: Siemens MAGNETOM Tim Trio 3T. Golden-angle radial stack-of-stars at 4x acceleration.
Not for clinical use. Images shown are of measurements reconstructed with baseline and RAM 3D.
Accelerated cardiac multi-coil MRI

Accelerated brain multi-coil MRI

Non-Cartesian accelerated breast MRI